Elecmetric

Buck and Boost Converter Formulas: Duty Cycle

Buck and boost converter formulas: duty cycle, inductor ripple current, input current with efficiency and the inductor for a ripple target, with examples.

The formulas

To findBuck (step-down)Boost (step-up)
Duty cycle D (ideal, continuous mode)D = Vout / VinD = 1 − Vin / Vout
Inductor ripple currentΔIL = (Vin − Vout) × D / (L × f)ΔIL = Vin × D / (L × f)
Inductor for a ripple targetL = (Vin − Vout) × D / (f × ΔIL)L = Vin × D / (f × ΔIL)
Input currentIin = Vout × Iout / (Vin × η)Iin = Vout × Iout / (Vin × η)

D is the fraction of each switching period that the switch is on, f the switching frequency in hertz, L the inductance in henries and η the efficiency as a fraction. The formulas are for ideal switches in continuous conduction mode and ignore the diode and switch drops, so the real duty cycle is a little higher. A common design choice is a ripple current of 20% to 40% of the output current for a buck converter.

Worked example: buck, 12 V to 5 V

An inductor of 22 µH at 500 kHz.

  1. D = 5 / 12 = 0.4167
  2. ΔIL = (12 − 5) × 0.4167 / (22 × 10⁻⁶ × 500,000) = 0.2652 A peak to peak

Worked example: boost, 5 V to 12 V at 1 A

The same inductor and frequency, with an efficiency of 90%.

  1. D = 1 − 5 / 12 = 0.5833
  2. ΔIL = 5 × 0.5833 / (22 × 10⁻⁶ × 500,000) = 0.2652 A
  3. Iin = 12 × 1 / (5 × 0.9) = 2.667 A, so the inductor must carry about 2.799 A at its peak

Boost duty cycle for a 5 V input

Output voltageDuty cycle
6 V0.1667
9 V0.4444
12 V0.5833
15 V0.6667
24 V0.7917

Frequently asked questions

Why is the boost input current higher than the output current?

The power is nearly the same at both ends. A lower input voltage needs a proportionally higher current, and the losses add to it.

What happens at a high duty cycle in a boost converter?

The gain from real losses stops the output rising as predicted, and the control becomes difficult above about 85% to 90%. Use another topology for a large step-up.

How do I pick the inductor?

Choose the inductance for the ripple you accept, then a part with a saturation current above the peak current and a low DC resistance.

What is discontinuous conduction mode?

At light load the inductor current reaches zero in each cycle. The duty-cycle formulas then no longer apply, and the output depends on the load.

Related

Inductor FormulasCapacitor FormulasRectifier Ripple FormulasElectronics and instrumentation calculatorsThree-Phase Power FormulasPower Factor and the Power TriangleAC Circuit Formulas: Reactance and ImpedanceVoltage Drop Formulas for CablesTransformer Formulas: Current and Fault LevelInduction Motor FormulasLighting Formulas: Lux, Lumens and CandelaBattery Formulas: Capacity and RuntimeSolar PV Formulas: Array Size and StringsEarthing Formulas: Earth Rod and Fault LoopCable Size Formulas: Current and Short-CircuitEnergy and Cost Formulas: kWh and PaybackGenerator Formulas: kVA, Current and FuelUPS Formulas: kVA, DC Current and BatteryHarmonics Formulas: THD and True Power FactorShort-Circuit Formulas: Fault Level by MVAUnbalance Formulas: Voltage and Neutral CurrentResistor Formulas: Series, Parallel, DividerMotor Starting Formulas: DOL, Star-DeltaCircuit Breaker Formulas: Rating and TripCooling Formulas: Airflow and Heat LoadHeating Formulas: Energy and Heater PowerPer-Unit Formulas: Base Values and ImpedanceLED Formulas: Resistor Value and PowerConduit Fill Formulas: Percent Fill and SizeLightning Protection Formulas: Rolling SphereTransformer Efficiency and Regulation FormulasPump Formulas: Hydraulic, Shaft and Motor PowerFan Formulas: Air Power and Affinity LawsRMS, Peak and Average Value FormulasResonance Formulas: Frequency, Q, BandwidthMotor Efficiency Formulas: Input and SavingsDemand, Load and Diversity Factor FormulasCable Tray Fill Formulas: Area and Cable CountConductor Resistance Formulas and TemperatureTransmission Line Formulas: Drop and LossesStar-Delta Conversion Formulas for Resistors4-20 mA Loop Formulas: Scaling and ResistorCable Loss Formulas: Power and Annual CostOp-Amp Formulas: Inverting and Non-Inverting555 Timer Formulas: Frequency and Duty CycleThévenin and Norton FormulasWheatstone Bridge Formulas: Balance and OutputConductor Force Formulas: Short-Circuit ForcesCT Burden Formulas: Lead Resistance and VAGear and Belt Drive Formulas: Speed and TorqueSkin Effect Formulas: Skin DepthRC Filter Formulas: Cutoff Frequency and GainHeat Sink Formulas: Junction TemperatureBattery Pack Formulas: Series and ParallelMotor Acceleration Time FormulasZener Regulator Formulas: Series ResistorBJT Bias Formulas: Voltage Divider BiasPt100 RTD Formulas: Resistance and TemperatureNTC Thermistor Formulas: Beta EquationFusing Current Formulas: Wire Fuse EstimateFlywheel Formulas: Stored EnergyLinear Regulator Formulas: Power and EfficiencyMOSFET Loss Formulas: Conduction and SwitchingRelay Coil Formulas: Current and ResistorTransformer Inrush Current FormulasBattery Charge Time FormulasWind Turbine Power Formulas: Betz LimitDetuning Reactor Formulas: Capacitor BanksTransformer Tap Changer FormulasCable Pulling Tension FormulasInsulation Resistance Formulas: PI and DARPower Transfer and Power Angle FormulasSolar Panel Temperature Derating FormulasVoltage Change and Flicker FormulasSoft Starter and VFD Sizing FormulasEarth Fault Loop and RCD FormulasBattery Internal Resistance FormulasBusbar Size and Short-Circuit FormulasADC Resolution and Sampling FormulasCapacitor Switching Inrush FormulasCable Charging Current FormulasSolar DC to AC Ratio FormulasMeasurement Uncertainty FormulasParallel Transformer Load Sharing FormulasPeukert Law and Battery Runtime FormulasCapacitor Discharge Time FormulasHydraulic Power and Cylinder Force FormulasThermocouple Voltage FormulasTransformer Vector Group FormulasPower Supply Hold-Up Time FormulasHoist and Lift Power FormulasCompressor Power FormulasRectifier Bridge Sizing FormulasPCB Trace Width and Current FormulasHeat Pump COP FormulasSound Level and dB Addition FormulasDuty Cycle and RMS Load FormulasSupercapacitor Energy FormulasStep and Touch Voltage FormulasContactor Sizing FormulasInverter-Fed Motor Cable FormulasPneumatic Cylinder Force and Air UseBusbar Temperature Rise FormulasMotor Temperature Rise FormulasBattery Storage Round-Trip EfficiencyThermal Time Constant FormulasSolar Charge Controller Sizing FormulasPoint Illuminance FormulasGenerator Droop and Load Sharing FormulasTwo-Wattmeter Method FormulasVFD Braking Resistor FormulasLoad Bank Test FormulasTransformer Cooling Class Rating FormulasEnergy Meter Multiplier FormulasOvercurrent Relay Curve FormulasSingle-Tuned Harmonic Filter FormulasCable Sheath Circulating Current FormulasDifferential Protection Slope FormulasEarth Electrode Spacing FormulasSolar Array Row Spacing FormulasDC Lighting Voltage Drop FormulasTransformer Loss of Life FormulasMotor Start Voltage Dip in the Cable FormulasNeutral Earthing Resistor FormulasCable I²t Withstand Check FormulasMotor Locked-Rotor Code Letter FormulasSynchronous Speed and Pole FormulasBattery C-Rate and Cycle Life FormulasEV Charging Time FormulasConveyor Belt Power FormulasParallel Plate Capacitor FormulasSolenoid and Coil Inductance FormulasPower Factor Correction Payback FormulasTransformer Through-Fault Current FormulasTransformer EMF Equation FormulasDelta-Star Resistor Conversion FormulasCurrent Shunt Resistor FormulasSolar Energy Yield and Degradation FormulasElectrolysis and Faraday’s Law FormulasAGL Series Circuit Load and CCR Sizing FormulasAGL Maximum Fittings on a CCR FormulasAGL Isolating Transformer FormulasAGL CCR Input Power and Energy FormulasAGL Brightness Step FormulasAGL Lamp Life FormulasComplex Number Formulas: Polar and RectangularPhasor Addition Formulas: Sum and DifferencePercentage Error Formulas for MeasurementsTrigonometry Formulas for Electrical EngineersMean and Standard Deviation FormulasQuadratic, Logarithm and Power FormulasPercentage, Ratio and Rounding FormulasProbability, Combinations and Binomial FormulasConversion Centre

Tell us how to improve this page

This opens your email app. Nothing is sent until you press send.