Breaker Rating Selection Calculator

Smallest standard breaker rating at or above the design current. With the formula, a worked example and typical values.

Design current 400.94 A, margin factor 1 gives
500 A

Estimate only. Not engineering or safety advice. Check the result against the applicable standard and the equipment data, and have a competent engineer review it before it is relied on. Terms of use.

Open in the calculator with these values

About this calculator

This page calculates breaker rating from design current. Change any value or its unit and the result updates. The steps below show the working for the default values, so you can check each line against your own method.

Limits of this calculator

Selection on current only. Breaking capacity, trip curve and discrimination are separate checks.

Cross-check: 85 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review.

Verification status: Indicative

Indicative. Estimation only; further engineering checks are required. Basis: Selection on current only; breaking capacity, trip curve and discrimination are not checked.

What this calculator checks

What remains unverified

Verification register entry

Calculation authorRahul Sharma (author)
Technical reviewNo independent technical review has been carried out
Individual professional approvalNot recorded
Formula referencenot recorded
Standard and editionIEC 60364-4-43; IEC 60947-2, IEC 60364-4-43:2023 Ed 4.0; IEC 60947-2:2024 Ed 6.0
Standard review statePublic-scope screened; licensed clause review still pending
Scope-screening noteOvercurrent protection and LV circuit-breaker product requirements are relevant. The calculator only rounds a user-margined current to a nominal rating; it does not check breaking capacity, trip curves, selectivity or local adoption.
Cross-check test cases85 reference vectors (tests/reference_vectors.json)
Review datenot recorded
Next review datenot recorded
StatusIndicative

Needed before this calculator can be marked Verified: reviewer name, qualification and review date; licensed clause-by-clause standard review; exact formula reference; formula source (textbook or standard); next review date.

Formula

In = smallest standard rating ≥ I × margin

Worked example

InputValue
Design current400.94 A
Margin factor1
  1. Required = I × margin = 400.94 × 1 = 400.94 A
  2. Next standard rating ≥ 400.94 A is 500 A

Assumptions

Selection on current only. Breaking capacity, trip curve and discrimination are separate checks.

Inputs and results

InputUnitAllowed or shownNote
Design currentAgreater than 0 A
Margin factor(number)1 or more, up to 21.0 selects on design current; 1.25 adds 25% for continuous loads
ResultUnitAllowed or shownNote
Breaker ratingAShown to 0 decimal places

How it is calculated

Each input is converted to the base unit of its quantity, the formula above is applied in the order shown in the worked example, and each result is shown in the unit you choose. Results are held at full precision and rounded only for display, except where a step selects a standard size, as the worked example shows. A value outside its allowed range is refused with a message instead of giving a result.

How the result changes with design current

Design current (A)Breaker rating (A)
40.150
100100
200200
401500
8021,000
1,6001,600
4,010—

Other inputs are the same as in the worked example above.

Standards and further reading

This is a first estimate. A protection study and the manufacturer's ratings and time-current curves decide the final selection. These are named as background reading. Elecmetric does not embed clause text or rating tables, and the reviewer record for this calculator is separate from this list.

Frequently asked questions

What do I need to enter?

Enter design current. Change the unit of a value with its selector and the result stays the same.

What does this calculator assume?

Standard ratings: 6, 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 200, 250, 320, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3200, 4000 A. Rating must also not exceed the cable current capacity.

Which calculators should I use next?

Common next steps are Voltage Drop. The related links at the bottom of this page open them.

How accurate are the results?

Every figure comes from the same tested engine as the Elecmetric calculators and is meant for estimating. 85 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review. Check design values against the standard and the equipment data you work to.

Formula guides and reference

Longer explanations with worked examples and tables, written for the same topic.

More Electrical Protection calculatorsAll engineering calculatorsBreaker Rating Selection in Elecmetric

Tell us how to improve this page

This opens your email app. Nothing is sent until you press send.