Elecmetric

RC Filter Cutoff Calculator

Cutoff frequency of a first-order RC filter, with the gain and phase at a chosen frequency. With the formula, a worked example and typical values.

Resistance 1 kΩ, capacitance 100 nF, frequency of interest 1,000 Hz, filter type Low-pass gives
Cutoff frequency: 1,591.5 Hz · Gain at the frequency of interest: -1.45 · Phase shift: -32.1

Estimate only. Not engineering or safety advice. Check the result against the applicable standard and the equipment data, and have a competent engineer review it before it is relied on. Terms of use.

Open in the calculator with these values

About this calculator

This page calculates cutoff frequency, gain at the frequency of interest and phase shift from resistance, capacitance, frequency of interest and filter type. Change any value or its unit and the result updates. The steps below show the working for the default values, so you can check each line against your own method.

Limits of this calculator

A load resistance or source impedance shifts the real cutoff. Keep the load at least ten times R.

Cross-check: 6 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review.

Verification status: Engineering reference

Engineering reference. Formula and method documented and tested against separately coded reference calculations. Not yet Verified: the evidence listed on this page is still needed.

What this calculator checks

What remains unverified

Verification register entry

Calculation authorRahul Sharma (author)
Technical reviewNo independent technical review has been carried out
Individual professional approvalNot recorded
Formula referencenot recorded
Standard and editionNot applicable: Textbook circuit identity (Ohm's law, power, series/parallel, AC circuit theory); no governing standard
Standard review stateNot applicable
Scope-screening notenot recorded
Cross-check test cases6 reference vectors (tests/reference_vectors.json)
Review datenot recorded
Next review datenot recorded
StatusEngineering reference

Needed before this calculator can be marked Verified: reviewer name, qualification and review date; exact formula reference; formula source (textbook or standard); next review date.

Formula

fc = 1 / (2π R C) Low-pass: |H| = 1 / √(1 + (f/fc)²), φ = −atan(f/fc) High-pass: |H| = (f/fc) / √(1 + (f/fc)²), φ = atan(fc/f)

Worked example

InputValue
Resistance1 kΩ
Capacitance100 nF
Frequency of interest1,000 Hz
Filter typeLow-pass
  1. fc = 1 / (2π × 1,000 × 100 nF) = 1,591.55 Hz
  2. f / fc = 1,000 / 1,591.55 = 0.6283
  3. Gain = -1.445 dB, phase = -32.14 °

Assumptions

A load resistance or source impedance shifts the real cutoff. Keep the load at least ten times R.

Inputs and results

InputUnitAllowed or shownNote
ResistancekΩgreater than 0 kΩ
CapacitancenFgreater than 0 nF
Frequency of interestHzgreater than 0 Hz
Filter type(choice)Low-pass; High-pass
ResultUnitAllowed or shownNote
Cutoff frequency (−3 dB)HzShown to 1 decimal place
Gain at the frequency of interest (dB)(number)Shown to 2 decimal places
Phase shift (°)(number)Shown to 1 decimal place

How it is calculated

Each input is converted to the base unit of its quantity, the formula above is applied in the order shown in the worked example, and each result is shown in the unit you choose. Results are held at full precision and rounded only for display, except where a step selects a standard size, as the worked example shows. A value outside its allowed range is refused with a message instead of giving a result.

How the result changes with resistance

Resistance (kΩ)Cutoff frequency (Hz)Gain at the frequency of interestPhase shift
0.115,915.5-0.02-3.6
0.256,366.2-0.11-8.9
0.53,183.1-0.41-17.4
11,591.5-1.45-32.1
2795.8-4.11-51.5
4397.9-8.64-68.3
10159.2-16.07-81

Other inputs are the same as in the worked example above.

Standards and further reading

These are textbook circuit relationships. The component data sheet sets the real limits, tolerances and ratings, and takes priority over the calculated value.

Frequently asked questions

What do I need to enter?

Enter resistance, capacitance, frequency of interest and filter type. Change the unit of a value with its selector and the result stays the same.

What does this calculator assume?

Ideal source and an unloaded output. First-order filter, so 20 dB per decade roll-off.

Which calculators should I use next?

Common next steps are RC Time Constant and Cutoff and Inductive and Capacitive Reactance. The related links at the bottom of this page open them.

How accurate are the results?

Every figure comes from the same tested engine as the Elecmetric calculators and is meant for estimating. 6 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review. Check design values against the standard and the equipment data you work to.

Formula guides and reference

Longer explanations with worked examples and tables, written for the same topic.

More Electronics and Instrumentation calculatorsAll engineering calculatorsRC Filter Cutoff in Elecmetric

Tell us how to improve this page

This opens your email app. Nothing is sent until you press send.