Capacitor and Inductor Energy Calculator
Energy stored in a charged capacitor and in a current-carrying inductor. With the formula, a worked example and typical values.
Try your own numbers
Estimate only. Not engineering or safety advice. Check the result against the applicable standard and the equipment data, and have a competent engineer review it before it is relied on. Terms of use.
Open in the calculator with these values
About this calculator
This page calculates capacitor energy and inductor energy from capacitance, capacitor voltage, inductance and inductor current. Change any value or its unit and the result updates. The steps below show the working for the default values, so you can check each line against your own method.
Limits of this calculator
Stored energy sets the discharge hazard for capacitor banks, and the arcing energy when an inductive circuit is opened.
Cross-check: 6 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review.
Verification status: Engineering reference
Engineering reference. Formula and method documented and tested against separately coded reference calculations. Not yet Verified: the evidence listed on this page is still needed.
What this calculator checks
- The arithmetic of the published formula for the values you entered, in the units shown.
What remains unverified
- That the inputs suit your application. Take ratings, resistances and constants from the manufacturer data sheet or project specification.
Verification register entry
| Calculation author | Rahul Sharma (author) |
|---|---|
| Technical review | No independent technical review has been carried out |
| Individual professional approval | Not recorded |
| Formula reference | not recorded |
| Standard and edition | Not applicable: Textbook circuit identity (Ohm's law, power, series/parallel, AC circuit theory); no governing standard |
| Standard review state | Not applicable |
| Scope-screening note | not recorded |
| Cross-check test cases | 6 reference vectors (tests/reference_vectors.json) |
| Review date | not recorded |
| Next review date | not recorded |
| Status | Engineering reference |
Needed before this calculator can be marked Verified: reviewer name, qualification and review date; exact formula reference; formula source (textbook or standard); next review date.
Formula
Worked example
| Input | Value |
|---|---|
| Capacitance | 100 µF |
| Capacitor voltage | 400 V |
| Inductance | 50 mH |
| Inductor current | 10 A |
- Ec = ½ × 100 µF × 400² = 8 J
- El = ½ × 50 mH × 10² = 2.5 J
Assumptions
- Ideal components
Stored energy sets the discharge hazard for capacitor banks, and the arcing energy when an inductive circuit is opened.
Inputs and results
| Input | Unit | Allowed or shown | Note |
|---|---|---|---|
| Capacitance | µF | greater than 0 µF | |
| Capacitor voltage | V | greater than 0 V | |
| Inductance | mH | greater than 0 mH | |
| Inductor current | A | greater than 0 A |
| Result | Unit | Allowed or shown | Note |
|---|---|---|---|
| Capacitor energy | J | Shown to 3 decimal places | |
| Inductor energy | J | Shown to 3 decimal places |
How it is calculated
Each input is converted to the base unit of its quantity, the formula above is applied in the order shown in the worked example, and each result is shown in the unit you choose. Results are held at full precision and rounded only for display, except where a step selects a standard size, as the worked example shows. A value outside its allowed range is refused with a message instead of giving a result.
How the result changes with capacitance
| Capacitance (µF) | Capacitor energy (J) | Inductor energy (J) |
|---|---|---|
| 10 | 0.8 | 2.5 |
| 25 | 2 | 2.5 |
| 50 | 4 | 2.5 |
| 100 | 8 | 2.5 |
| 200 | 16 | 2.5 |
| 400 | 32 | 2.5 |
| 1,000 | 80 | 2.5 |
Other inputs are the same as in the worked example above.
Standards and further reading
These are textbook relationships (Ohm's law, series and parallel networks, AC phasors, three-phase quantities). No standard sets the method; standards apply when the result feeds a design, for example cable or protection selection.
Frequently asked questions
What do I need to enter?
Enter capacitance, capacitor voltage, inductance and inductor current. Change the unit of a value with its selector and the result stays the same.
What does this calculator assume?
Ideal components.
Which calculators should I use next?
Common next steps are RC Time Constant and Cutoff and Inductive and Capacitive Reactance. The related links at the bottom of this page open them.
How accurate are the results?
Every figure comes from the same tested engine as the Elecmetric calculators and is meant for estimating. 6 reference cases, calculated from textbook formulas coded separately from the engine by the same author, agree with this calculator. This is not an independent review. Check design values against the standard and the equipment data you work to.
Formula guides and reference
Longer explanations with worked examples and tables, written for the same topic.
- Capacitor Formulas: Energy and RC Time Constant: Capacitor formulas for charge, stored energy, series and parallel capacitance and the RC time constant
- Inductor Formulas: Energy and L/R Time Constant: Inductor formulas: stored energy, L/R time constant, current rise after switch-on, series and parallel inductance
- Capacitor Discharge Time Formulas: Capacitor discharge formulas: the time constant of a discharge resistor, the voltage after a time
More Electrical Fundamentals calculatorsAll engineering calculatorsEnergy in a Capacitor and an Inductor in Elecmetric